Show Summary Details
Page of

Case 56: Autoimmune Small Fiber Neuropathy with Positive Ganglionic Acetylcholine Receptor Antibody 

Case 56: Autoimmune Small Fiber Neuropathy with Positive Ganglionic Acetylcholine Receptor Antibody
Chapter:
Case 56: Autoimmune Small Fiber Neuropathy with Positive Ganglionic Acetylcholine Receptor Antibody
Author(s):

Peter Novak

DOI:
10.1093/med/9780190889227.003.0061
Page of

PRINTED FROM OXFORD MEDICINE ONLINE (www.oxfordmedicine.com). © Oxford University Press, 2020. All Rights Reserved. Under the terms of the licence agreement, an individual user may print out a PDF of a single chapter of a title in Oxford Medicine Online for personal use (for details see Privacy Policy and Legal Notice).

date: 30 March 2020

In this patient, autonomic tests were positive for small fiber neuropathy, mixed, length-dependent. Clinical workup was positive for ganglionic acetylcholine receptor antibody. Patient subsequently improved with immunotherapy with intravenous immunoglobulins.